Supermarket Applications |
|
ANSI/ASHRAE 15 and Mechanical Code
Compliance |
|
Genesis International manufactures a number of
control systems designed for the staging and control of the refrigeration
equipment within a Supermarket. |
|
Sherlock Refrigerant Gas Monitoring System
Walk-In Monitoring System |
Fixed Panels
Sensors |
Provides monitoring solutions for refrigeration
machinery rooms and enclosed refrigerated room.
ASHRAE 15
Compliance |
|
|
Compressor Rack Control |
|
Genesis International manufactures a number of
control systems designed for the staging and control of the refrigeration
rack systems. |
|
Wizard Compressor Control System |
WCC |
The
WCC is designed to stage up to seven parallel compressors / unloaders based
upon Suction Pressure. |
-
Stages an additional compressor (Satellite or Booster Compressor)
based upon room temperature.
-
Provides a number of rack alarms to include Suction Pressure, Head Pressure
and Receiver Level.
|
|
Wizard Compressor Control System -
Temperature Control |
WCC-T |
The
WCC-T is designed to stage up to seven parallel compressors / unloaders
based upon room temperature. |
-
Stages an additional compressor (Satellite or Booster Compressor) based upon
room temperature.
-
Provides a number of rack alarms to include Suction Pressure, Head Pressure
and Receiver Level
|
|
Wizard Compressor Control System - Plus |
WCC-Plus |
The
WCC-Plus is designed to stage up to eleven parallel compressors / unloaders
based upon Suction Pressure. |
-
Stages an additional compressor (Satellite or Booster Compressor) based upon
room temperature.
-
Provides a number of rack alarms to include Head Pressure, Oil Failure for
up to four compressors, and Receiver Level.
|
|
Wizard Condensing Unit Control System |
WCUC |
The
WCUC is designed to stage up to seven fixed speed, parallel compressors
unloaders and up to seven condenser stages. |
-
Stages fixed speed compressors/unloaders
-
Operates fixed or floating (SPR)
suction pressure.
-
Stages an additional compressor (Satellite Compressor) based upon
room temperature.
-
Stages a remote condenser with up to seven condenser stages (fan, pump or damper) based upon either a fixed or floating head pressure setpoint
or by deadband settings.
-
Provides a number of rack alarms to include Suction Pressure, Head Pressure
and Receiver Level.
|
|
Wizard Rack Control System |
WRC |
The
WRC is designed to stage up to seven fixed speed, parallel compressors
unloaders and up to seven condenser stages. |
-
Stages fixed speed compressors/unloaders
-
Operates fixed or floating (SPR)
suction pressure.
-
Stages an additional compressor (Satellite Compressor) based upon
room temperature.
-
Stages a remote condenser with up to seven condenser stages (fan, pump or damper) based upon either a fixed or floating head pressure setpoint
or by deadband settings.
-
Condenser control hardware is mountable either on the condenser or on the
rack.
-
Provides a number of rack alarms to include Suction Pressure, Head Pressure
and Receiver Level.
|
|
Multi-Plex Defrost Clocks |
|
Defrost Manager |
DM-8
DM-16
DM-24
DM-32 |
The
Defrost Manager is designed to control up to 32 defrost circuits in
increments of 8. The control circuitry for each group of eight can be
mounted remotely from the control panel. |
-
Each
circuit can be programmed for up to 12 cycles per day of either Hot Gas,
Electric or Off-Time Defrost.
-
Provides a temperature alarm for each circuit.
|
|
Temperature Monitor and Alarming |
|
Gencom3000 Supervisory and Alarming Computer
System |
GEN3000 |
The Gencom3000 Supervisory and Alarming Computer
System is designed to monitor up to 2000 temperature and refrigeration
system data points, activate alarm, and log all monitored data. |
|
|
Walk-In Monitoring System |
WIM
WIM2
WIM3 |
The
Walk-In Monitoring System is designed to monitor and alarm for most
mechanical and safety issues within one, two or three independent walk-in
coolers/freezers. |
Provides alarms for Temperature,
Refrigerant Leaks, Door Ajar and Entrapment all within a single control
panel.
The WIM-DL provides temperature data-logging
with the storage capacity of up to 4000 entries.
The WIM-H provides Humidity monitoring and
alarming.
|
|
AutoDialer |
AD-1104
AD 1104-R
AD-1108
AD-1108-R |
The AutoAlarm Dialer is an inexpensive method of broadcasting an alarm condition within a refrigerated warehouse, grocery store or convenience market. |
Calls from 4 to 8 numbers to verbally report alarm
conditions
Can monitor up to eight inputs.
Dry Contact Alarm Relay Closures
Status Switches
Doors
Temperature Sensors
Humidity Sensor
Moisture Sensor
|
|
Temperature Control - Room Controls |
|
Walk-In Control System |
WIC
WIC2
WIC3 |
The
Walk-In Control System provides the same alarming capabilities as the
WIM(2,3), excluding entrapment, with the addition of temperature control and
Electric or Off-Time defrost for one, two or three temperature zones or
walk-in cooler/freezers.
|
-
Provides pilot-duty rated control relays for Evaporator Fans and
Defrost Circuits.
Provides 30A, 1 ph control relays for each
defrost and fan circuit (available only with the one or two zone units)
Provides 30A, 3 ph control relays for each
defrost and fan circuit (available only with the one or two zone units)
Provides a reheat circuit for maintaining of
critical temperature systems.
|
|
HVAC Air Handler Controls |
|
ComfortMiser Air Handler Control System |
CM1-8
CM1-16
CM2-8
CM2-16 |
The
ComfortMiser Airhandler Control System will control the temperature and
humidity of an airhandler system.
|
-
Up to 6
AC stages in a First On-Last Off (FILO) or First On-First Off (FIFO) control
scheme.
-
De-humidification using of AC loading or an external de-humidification
device.
Controls Heat Reclaim (reclaimed heat from the
discharge of the store refrigeration system).
Controls Booster Heat (gas or electric).
Controls an economizer damper based upon outdoor
temperature and humidity levels.
Cycles control circuits for external heating
systems (vestibule, sidewalk) based upon outdoor temperatures.
Turns on/off the anti sweat circuits of the
refrigerated cases based upon the internal humidity levels.
Provides load-shedding control of the air
handler during periods of peak electrical demand.
|
|
Light and Energy Management System |
|
Light and Energy Management System |
LM-8
LM-16
LM-24
LM-32 |
The
Light and Energy Management System provides automatic control of a
facility's lighting system. |
-
Controls up to 32 lighting circuits.
Nine (9) daily schedules for each circuit
Up to three on/off cycles per day.
Provides holiday scheduling
Emergency schedule override
Manual schedule override.
|