WCC-P7  Plus Control Configuration in a NEMA 1 Enclosure.  Controls up to seven compressor or a combination of seven compressors and unloaders.  Suction Pressure Transducer range from 0 to 200 PSIG for Medium Temperature applications.

WCC-P7-LT  Plus Control configuration for Low Temperature Applications in a NEMA 1 Enclosure.  Controls up to seven compressor or a combination of seven compressors and unloaders.  Suction Pressure Transducer range from -14.7 to 100 PSIG for Low Temperature applications.

WCC-P7-PM  Plus Control configuration in a Panel Mountable configuration.  Control faceplate and Control Input/Output/Power backplate allow for separate mounting into a field supplied enclosure. Controls up to seven compressor or a combination of seven compressors and unloaders.  Suction Pressure Transducer range from 0 to 200 PSIG for Medium Temperature applications.

WCC-P7-LT-PM  Plus Control configuration for Low Temperature Applications in a Panel Mountable configuration.  Control faceplate and Control Input/Output/Power backplate allow for separate mounting into a field supplied enclosure. Controls up to seven compressor or a combination of seven compressors and unloaders.  Suction Pressure Transducer range from -14.7 to 100 PSIG for Low Temperature applications.                      

WCC-P7-4  Plus Control configuration in a NEMA 4X Enclosure.  Controls up to seven compressor or a combination of seven compressors and unloaders.  Suction Pressure Transducer range from 0 to 200 PSIG for Medium Temperature applications.

WCC-P7-LT-4  Plus Control configuration for Low Temperature Applications in a NEMA 1 Enclosure.  Controls up to seven compressor or a combination of seven compressors and unloaders.  Suction Pressure Transducer range from -14.7 to 100 PSIG for Low Temperature applications.

WCC-P7-H  Plus Control configuration in a NEMA 1 Enclosure.  Control kit includes a Head Pressure Transducer for High and Low Head monitoring and alarming.  Suction Pressure Transducer range from 0 to 200 PSIG for Medium Temperature applications.  Head Pressure Transducer range from 0 to 500 PSIG.

WCC-P7-LT-H  Plus Control configuration for Low Temperature Applications in a NEMA 1 Enclosure.  Control kit includes a Head Pressure Transducer for High and Low Head monitoring and alarming.  Suction Pressure Transducer range from -14.7 to 100 PSIG for Low Temperature applications.  Head Pressure Transducer range from 0 to 500 PSIG.

WCC-P7-H-PM  Plus Control configuration in a Panel Mountable configuration.  Control faceplate and Control Input/Output/Power backplate allow for separate mounting into a field supplied enclosure. Control kit includes a Head Pressure Transducer for High and Low Head monitoring and alarming.  Suction Pressure Transducer range from 0 to 200 PSIG for Medium Temperature applications.  Head Pressure Transducer range from 0 to 500 PSIG.

WCC-P7-LT-H-PM  Plus Control configuration for Low Temperature Applications in a Panel Mountable configuration.  Control faceplate and Control Input/Output/Power backplate allow for separate mounting into a field supplied enclosure. Control kit includes a Head Pressure Transducer for High and Low Head monitoring and alarming.  Suction Pressure Transducer range from -14.7 to 100 PSIG for Low Temperature applications. Head Pressure Transducer range from 0 to 500 PSIG.                              

WCC-P7-H-4  Plus Control configuration in a NEMA 4X Enclosure.  Control kit includes a Head Pressure Transducer for High and Low Head monitoring and alarming.  Suction Pressure Transducer range from 0 to 200 PSIG for Medium Temperature applications.  Head Pressure Transducer range from 0 to 500 PSIG.

WCC-P7-LT-H-4  Plus Control configuration for Low Temperature Applications in a NEMA 1 Enclosure.  Control kit includes a Head Pressure Transducer for High and Low Head monitoring and alarming.  Suction Pressure Transducer range from -14.7 to 100 PSIG for Low Temperature applications.  Head Pressure Transducer range from 0 to 500 PSIG.

Oil Pressure Monitoring

Additional pressure transducers for Oil Pressure monitoring must be 0 - 200 PSIG, sold separately, maximum number of compressors to be monitored - 4. 

 

Genesis International, Inc. reserves the right to change product specifications and availability without notice.

Contact a factory representative for additional information on this and any other products.

Copyright © Genesis International Inc. All Rights Reserved.