Wizard Parallel Compressor Control System - Plus

12 Step

ENCLOSURE   MODEL             NEMA/IP     ELECTRICAL       POLLUTION

        #                  RATING       CATEGORY       PROTECTION

    WCC-P12              1                    II                        2  WCC-P12-4        4x / Ip67              II                        3

WCC-P12-PM            1                    II                        2

NEMA 1 Compliant Enclosure - This enclosure is intended for indoor use only primarily to provide a degree of protection against contact with the enclosed equipment. The enclosure is not designed to provide protection from water or to be placed in a hazardous environment. Mount only in Pollution Level 2 environments, ie. environmentally controlled offices, control rooms, or environmentally controlled machine rooms.DIMENSIONS    12"H x 9.5"W x 5.0"D Nema 1

 

NEMA 4X Compliant Enclosure - This enclosure is intended for either indoor or outdoor use, 0 to 50 °C, to provide a degree of protection against corrosion, windblown dust and rain, splashing water, and hose directed water.DIMENSIONS    14"H x 15"D x 8.2 "D Nema 4X

 

NEMA 1 Panel Mount Option - The control and display assemblies must be suitably mounted in an enclosure. The Faceplate may be surface mounted onto a Nema 1 enclosure. The IO Board Assembly must be mounted within an enclosure providing at least Nema 1 protection.

 

POWER             90 to 250VAC, 50/60 Hz, 2.5 Amps

INPUTS (All inputs use unpluggable screw terminals)                          Two (2) Control Pressure Transducers                                  Suction Pressure, 14.7in Vacuum to 100psig or 0 to 200psig                                  Four (4) Oil Pressure, 0 - 200 psig                                  Head Pressure, 0 - 500 psig                          Four (4) Configurable Oil Pressure Sensors                                  Four (4) Oil Pressure, 0 - 200 psig                                      or                                  Digital, Oil Pressure Control Switch Input (Dry Contact)                          Two (2) RTD Temperature Sensors                                  Room 1 - Suction Pressure Reset (SPR) Temperature, 2-wire thermistor, -40 to 150°F                                  Room 2 - Booster Compressor (Satellite) Temperature, 2-wire thermistor, -40 to 150°F                          One (1) Dry Contact - Defrost Status (AC Shutdown)                          One (1) Dry Contact - System Shutdown                          One (1) Receiver-CPR-Surge Vessel Level Indicator - Configurable                                  Digital, 4-20ma, voltage OUTPUTS          Twelve SPDT, 1 Form C, 250VAC, 3.15Amp relays OPERATING TEMPERATURE     20ºF - 120ºF OPERATING HUMIDITY              20% - 90% RH, non- condensing ALARMS             System Alarms (1 relay)

                                 Suction High/Low                                  Oil Pressure Low                                  Head Pressure High/Low                                  Room Temp High/Low                                  Receiver-CPR-Surge Vessel Level Low / Shutdown                                  Receiver Level High / Shutdown                                  System Internal Alarm Conditions

DISPLAY             2 lines by 20 characters Alphanumeric LCD with back light KEYPAD              5 tactile key switches:  Scroll up, Scroll down, Select/Change, Exit, Force Defrost Start/Advance ALARM INDICATORS       LCD DISPLAY         Name, description, and current reading of alarming sensor       BUZZER                  Piezo-electric, 90db @10ft, silenceable      STROBE LIGHT (Optional)       Mounted on top of the housing, activates during any alarm condition.

 

 