Product Categories

Refrigerant Gas Monitoring Panels - Fixed Systems

Refrigerant Gas Monitoring - Portable Systems

Compressor Condensing Unit Control Panels

Condenser Control Panels

Evaporator - Room - Zone Control Panels

Air-Handler, Chiller, and Energy Management Control Panels

Sensors

Breathing Apparatus and Accessories

Alarm Indication Equipment

Remote Monitoring and Communications

OEM - Original Manufactured Equipment

   

Wizard Parallel Compressor Control System

An all electronic control that can controls the operations of a up to seven parallel compressors/unloader stages in a single suction group

     

Text Box: WCC –  #  –  #  –  #  –  #  –  #  –  #
Line Callout 4 (Border and Accent Bar): Control Method - Pressure / Temperature
Pressure Control – 7 Stages                                 Blank
Press Ctl – 7 Steps, Comp. Stat Mon                        P7
Press Ctl – 7 Steps, Comp. Stat Mon                      P12
Temperature Control                                                T
Temp Control, Suction Mon                                    TS
Line Callout 4 (Border and Accent Bar): Communications Option
RS485 (Gencom) Remote Comm      (Standard)    blank RS232 Communications                                         232
Ethernet (Gencom) Comm                                         E
ModBUS Network Comm                                          M
BacNET Network Communications                           B
Text Box: Base Model
Compressor Control System                               WCC
Line Callout 4 (Border and Accent Bar): Enclosure Mounted Alarm Strobe Light Option
None (Standard)                                                   blank
Enclosure Mounted Strobe Light                                S
Line Callout 4 (Border and Accent Bar): Enclosure Option
Nema 1 (Standard)                                               blank
Panel Mount (Standard)                                         PM
Nema 4                                                                      4
Line Callout 4 (Border and Accent Bar): Pressure / Temperature Range
Medium Temp ( 0 to 200 PSIG Transducer)         blank
LowTemp ( -15 to 100 PSIG Transducer)                LT
Line Callout 3 (Border and Accent Bar): Head Pressure Monitoring
Head Pressure Monitoring                                         H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

     

                                                  

 

Genesis International, Inc. reserves the right to change product specifications and availability without notice.

Contact a factory representative for additional information on this and any other products.

Copyright © Genesis International Inc. All Rights Reserved.