EPC 2000 Multiplex Parallel Rack Control

CONTROL SYSTEM

  • Microprocessor based

  • Program logic stored within non-volatile Flash EEPROM or OTP EPROM

  1. Setpoints and system configuration stored within serial EEPROM

  2. Logged Data stored within Battery Backed Memory chip, minimum of 10 years storage life

  3. Clock is Y2K compliant, leap year compatible until year 2100 and is battery backed for a minimum of 5 years

  • Menu driven controls with all operating sequences and control algorithms included.

  • The control has non-volatile program memory and a battery backed clock in the event of a power outage.

  • All programmable options are installed via a Yes/No or Installed/Not-installed question.

  • Keypad -- Front Panel accessible with 15 tactile key switches.

  • Key Assignments --Up, Down, Enter, Pass code/+-, Specific Functions.

  • Display -- 16x2 character LCD with backlight. Backlight will shut off after 30 minutes. It will turn on when any key is pressed.

  • Power --120/208/240 VAC, 50/60hz 40VA

  • Housing -- Metal Cabinet, NEMA 1

INPUTS

  • Suction Pressure -- Up to 2 Suction Groups

  • Discharge, or Head, Pressure

  • Receiver Tank Level Sensor

  • Suction Pressure Reset Case Temperature Sensor -- 1 per suction group

  • Satellite Case Temperature Sensor --1 per Satellite Compressor

  • Liquid Line Drop Leg Temperature Sensor

  • Ambient Temperature Sensor

  • Heat Reclaim Relay Status

  • Gas Defrost Status

  • Auxiliary Alarm Inputs

  • Defrost Termination -- 1 per defrost circuit \par \tab \par

Pressure Transducers -- 3-wire, V+ Signal Ground, analog 1 to 6 VDC signal Ranges--0 to 100 PSI, 0 to 200 PSI, 0 to 500 PSI

Temperature Sensors -- 2-wire, Microprocessor based, -40 to 158 °F

Digital Inputs -- All Digital Inputs are low voltage, 5VDC open or close signal inputs. All digital signal sources are non-polarity specific.

Receiver Tank Level --3-wire, V+ Signal Ground, analog signal. Indicates 0 to 100%. Allowable input signals--1 to 2VDC, 0 to 5VDC, 1 to 6VDC

OUTPUTS--Control Relays

  • All Relay Outputs are 1 Form C SPDT rated for 250VAC and 3Amp per circuit.

  • Each relay circuit is fused with a 3Amp Slowblow fuse on the common leg.

  • All relay action is indicated by an LED on the PC board next to the relay.

  • All wiring terminals are un-pluggable Molex terminals.

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

                                                            Copyright ã Genesis International Inc. All Rights Reserved.
                                                                        Last Updated January 17, 2005 22:52:24

 

Genesis International, Inc. reserves the right to change product specifications and availability without notice.

Contact a factory representative for additional information on this and any other products.

Copyright © Genesis International Inc. All Rights Reserved.